The Allen-Bradley ControlLogix system differs from other logic control systems in that the ControlLogix system is capable of integrating an entire manufacturing environment, not just certain machines or lines within a factory.
ControlLogix Controllers
ControlLogix Communication Modules
ControlLogix Integrated Motion
ControlLogix I/O Modules
ControlLogix Power Supplies
ControlLogix Chassis
ControlLogix Software
The Allen-Bradley ControlLogix system differs from other logic control systems in that the ControlLogix system is capable of integrating an entire manufacturing environment, not just certain machines or lines within a factory. A simple ControlLogix system consists of a stand alone controller and input/output modules in a single chassis. More complex systems can have more than one controller in a chassis or multiple controllers and input/output modules in several chassis. These chassis can be part of an extended network interconnected with various communication modules and spread throughout an entire manufacturing facility. ControlLogix provides the total system, including discrete and analog input/output, control over drives, motion, processes, and even safety concerns. The ControlLogix system can be configured in standard formats, for harsh environments, and even with integrated safety features. It is a totally modular system that can be configured to meet the demands and concerns of any manufacturing facility. Designing the initial system, building it, and even modifying it at some future date can be done very cost-effectively, both in terms of initial equipment expense as well as significant savings realized in engineering the system and training those who will use it.
The entire ControlLogix system is a blend of several different modular components which are mounted in the system cabinet. Among these components are:
ControlLogix Controllers
ControlLogix Communication Modules
ControlLogix Integrated Motion
ControlLogix I/O Modules
ControlLogix Power Supplies
ControlLogix Chassis
ControlLogix Software
Configuring your ControlLogix system, whether it be for one machine, an assembly line, or an entire manufacturing facility, is rather straightforward. You will need to closely examine the relevant manufacturing blueprints, as well as all machine prints and electrical prints pertinent to the task at hand. Create a spreadsheet listing all operations requiring input and output points. Also note all specialty applications, such as motion control and temperature control, and the type of communications modules needed to interface with the various system components. After completing this spreadsheet you will be able to determine the amount of memory necessary, the number of input/output modules and communication modules needed, and all other aspects of your ControlLogix system. The following tables list the various options available to complete your ControlLogix system. The order in which they are presented is the most logical way to configure your system. For instance, you cannot determine which ControlLogix Controller(s) to select until you have analyzed the number of Input/Output modules needed.
Allen Bradley ControlLogix Controllers
Several options are available, including standard controllers, GuardLogix safety controllers, and ControlLogix-XT extreme temperature controllers. User memory options range from 2 MB to 32 MB.
You will need to select the appropriate controller with sufficient memory to operate your system. If there is any doubt, always select the next larger memory option. You'll also be choosing optional memory cards as needed. Controllers can be placed in any slot of a ControlLogix chassis, and multiple controllers can be mounted in the same chassis. Multiple controllers communicate with each other but can operate independently. Refer to the following tables for specifications. Controller USB ports are intended for temporary local programming. USB ports are not suited for permanent connections or hazardous locations.
Part Number | Description | User Memory |
1756-L71 | ControlLogix Controller with 1 built-in USB Port | 2 MB |
1756-L72 | 4 MB | |
1756-L73 | 8 MB | |
1756-L74 | 16 MB | |
1756-L75 | 32 MB | |
1756-L61 | ControlLogix Controller with 1 built-in RS-232 Port | 2 MB |
1756-L62 | 4 MB | |
1756-L63 | 8 MB | |
1756-L64 | 16 MB | |
1756-L65 | 32 MB | |
1756-L63XT | ControlLogix XT Controller for Extreme Temperatures/Extreme Environments | 8 MB |
1756-L73XT | 8 MB | |
1756-L61S | GuardLogix Safety Controllers | 2 MB Standard/1 MB Safety |
1756-L62S | 4 MB Standard/1 MB Safety | |
1756-L63S | 8 MB Standard/3.75 MB Safety | |
1756-L72S | 4 MB Standard/2 MB Safety | |
1756-L73S | 8 MB Standard/4 MB Safety | |
1756-LSP | GuardLogix Safety Partner/Use with 1756-L6xS GuardLogix Controllers | |
1756-L7SP | GuardLogix Safety Partner/Use with 1756-L7xS GuardLogix Controllers |
ControlLogix Controllers Standard Features
Feature | 1756-L61, L62, L63, L64, L65 | 1756-L71, L72, L73, L74, L75 |
Controller Tasks | 32 Tasks, 100 Programs/Task, Event Tasks: All Event Triggers | |
Built-In Communication Ports | (1) RS-232 Serial Port | (1) USB Port |
Communication Options | EtherNet/IP, ControlNet, DeviceNet, Data Highway Plus, Remote I/O, SynchLink, Third Party Process and Device Networks | |
Maximum Controller Connections | 250 | 500 |
Connections per Network Module | 100 ControlNet (1756-CN2/A); 40 ControlNet (1756-CNB; 256 EtherNet/IP, 128 TCP (1756-EN2x); 128 EtherNet/IP, 64 TCP (1756-ENBT) | |
Controller Redundancy | Full Support | |
Integrated Motion | EtherNet/IP Connection; SERCOS; Analog Options: Encoder, LDT, SSI | |
Programming Languages | Relay Ladder; Structured Text; Function Block; SFC | |
Optional Memory Cards | 1784-CF128: 128 MB | 1784-SD1: 1 GB; 1784-SD2: 2 GB |
Redundant ControlLogix Controllers
All ControlLogix controllers support controller redundancy. A redundant controller system requires two 1756 Chassis per redundant system with these identical features:
- Total number of slots
- Modules in same slots in each chassis
- Redundancy firmware in each chassis
- Two additional ControlNet Nodes outside the redundant chassis pair
- One 1756-RM Redundancy Module per chassis to support one 1756-L64 or L65 controller or one 1756-RM to support two 1756-L71, L72, L73, L74, L75, L61, L62 or L63 controllers
- Maximum seven communication modules. Choose from 1756-CN2/B, CN2R/B, EN2T, or EN2F Modules
- One 1756-RMCx cable
Allen Bradley ControlLogix Communication Modules
Available options include EtherNet/IP, ControlNet, DeviceNet, Data Highway Plus, Remote I/O, Foundation Fieldbus, Serial, DH-485, and SynchLink. Multiple communication modules can be installed in the ControlLogix system to allow control and/or sharing of data over different networks.
After determining the networks you will be using you will be able to select the communication modules your system will require and the necessary cables and network equipment. Remember to plan for extra modules and cables if you are designing a redundant system. It is possible to route a message through up to 4 different chassis (8 communication hops). A ControlLogix controller is not required in each chassis to accomplish this. The following tables list the various communication modules available to interface with your system. The first table lists normal usage applications for the industry protocol communications networks.
Communication Network Applications
Communication Network | Standard Applications |
EtherNet/IP | Plant Management (Material Handling) Configuration,Data Collection & Control/Single High Speed Network Time Critical Applications/No Established Schedule Inclusion of Commercial Technologies (Video over IP, etc.) Internet/Intranet Connection Integrated CIP Motion & Safety |
ControlNet | High Speed Transfer of Time Critical Data Between Controllers and I/O Devices Deterministic & Repeatable Data Delivery Media Redundancy Intrinsic Safety Redundant Controller Systems |
DeviceNet | Connection of Low-Level Devices to Controllers w/o Interfacing Through I/O Modules Data Sent As Needed More Diagnostics for Improved Data Collection & Fault Detection Less Wiring & Reduced Start-Up Time than Traditional Hard-Wired System |
Data Highway Plus | Plant Wide and Cell Level Data Sharing With Program Maintenance Data Sent on Regular Basis Transferring Information Between Controllers |
Remote I/O | Connections Between Controllers & I/O Adapters Data Sent on Regular Basis Distributed Control/Each Controller Has I/O & Communicates with Supervisory Controller |
Foundation Fieldbus | Fieldbus Transmitters & Actuators Closed Loop Control Process Automation |
EtherNet/IP Communication Modules
The EtherNet Industrial Protocol Network (EtherNet/IP) is an industry standard open network which supports both real time input/output messaging and message exchange. EtherNet/IP uses readily available standard EtherNet communication chips and/or physical media.
Part Number | EtherNet/IP Application | Media | Communication Rate | CIP Motion Axes (Max) | TCP/IP Connections | Logix Connections |
1756-EN2F | Bridge, Fiber | Fiber | 100 Mbps | 8 | 128 | 256 |
1756-EN2T | Bridge, Copper | Copper | 10/100 Mbps | 8 | 128 | 256 |
1756-EN2TR | Bridge, Copper, Embedded Switch | Dual Copper | 10/100 Mbps | 8 | 128 | 256 |
1756-EN3TR | Bridge, Copper, Embedded Switch | Dual Copper | 10/100 Mbps | 128 | 128 | 256 |
1756-ENBT | Bridge, Copper | Copper | 10/100 Mbps | – | 64 | 128 |
1756-EWEB | Web Server Module | Copper | 10/100 Mbps | – | 64 | 128 |
1756-EN2TXT | ControlLogix-XT Bridge, Copper, Extreme Environments | Copper | 10/100 Mbps | 8 | 128 | 256 |
EtherNet/IP Network Accessories
Part Number | EtherNet/IP Application | Specifications |
1585J-M8PBJM-x | RJ45 Patchcord; x = 2 (2m), x = 5 (5m), or x = 10 (10m) | 8 Conductor, Teal Riser PVC Cable (Flex Rated Cable Available) |
1585J-M8CC-H | RJ45 Insulation Displacement Connector (IDC) | 0.128... 0.325 mm2 (26... 22 AWG), Cat. 6, IDC, No Tool Required |
1585J-M8CC-C | RJ45 Crimp Connector With Boot, Quantity: 50 Pieces | 0.128... 0.205 mm2 (26... 24 AWG), Cat 5e, Crimp Tool Required |
1585Jcrimp | Crimp Tool | Use With 1585J-M8CC-C |
9300-RADES | Remote Access Dial-In Kit | 56 Kbps Modem Connection With: Pre-Configured Modem, Communication Module, DIN Rail Mounting Hardware, and Associated Cables |
ControlNet Communication Modules
The ControlNet network provides high speed capabilities by combining the best aspects of an input/output network and a peer-to-peer network. ControlNet features deterministic, repeatable transfers of critical control data. The modules with 128 Logix connections also have an additional 3 connections reserved for redundant control. For the modules with 64 Logix connections it is recommended to use only 40 to 48 of these for input/output connections.
Part Number | ControlNet Application | Communication Rate | Logix Connections | Number of Nodes |
1756-CN2/B | Standard Media Bridge | 5 Mbps | 128 (+3) | 99 |
1756-CN2R/B | Redundant Media Bridge | 5 Mbps | 128 (+3) | 99 |
1756-CNB | Standard Media Bridge | 5 Mbps | 64 | 99 |
1756-CNBR | Redundant Media Bridge | 5 Mbps | 64 | 99 |
1756-CN2RXT | ControlLogix-XT Redundant Media Bridge | 5 Mbps | 128 (+3) | 99 |
DeviceNet Communication Module and Accessories
The DeviceNet network, as its name implies, provides communication connections between system devices. The devices can be as simple as sensors and actuators or more complex devices, such as controllers and computers.
Part Number | DeviceNet Application |
1756-DNB | DeviceNet Bridge Module Communication Rates: 125 Kbps (500 m max); 250 Kbps (250 m max); 500 Kbps (100 m max) Number of Nodes: 64 |
KwikLink Lite Flat Media | Newer, ODVA approved for wiring DeviceNet networks. Supports intermixing of DeviceNet cable types, such as round with flat. KwikLink Lite connectors provide insulation displacement. |
KwikLink Flat Media | Modular cabling with flat 4-wire cable and insulation displacement connectors (IDCs). System Nodes can be added without cutting or stripping trunkline. Eliminates need for predetermined cable lengths. |
Round Media | Round trunk cable is available in bulk spools or as pre-molded cable sets of various lengths. Round cable supports rugged and durable DeviceNet components, including stainless steel versions: 1. Thick trunk round cable provides maximum length DeviceNet trunk lines. 2. Thin trunk cable reduces maximum trunk line distances with a more compact installation. Thin cable outer jacket is TPE for added chemical resistance. |
Data Highway Plus and Remote Input/Output Communication Modules and Accessories
Part Number | Description | Communication Rate | DH+ Connections | RIO Connections | Logix Connections |
1756-DHRIO | DH+/Remote I/O | 57.6 Kbps, 115.2 Kbps, 230.4 Kbps | 32 DH+ messages per DH+ Module | Remote I/O Scanner: 32 logical rack /channel; 16 block-transfer/channel | 32 |
1756-RIO | Remote I/O | 57.6 Kbps, 115.2 Kbps, 230.4 Kbps | -- | Remote I/O Scanner/Adapter: 32 physical racks (0... 76), any rack size and/or block transfers | 10 Scheduled Input/Output |
1756-DHRIOXT | Extended Temperature DH+/Remote I/O | 57.6 Kbps, 115.2 Kbps, 230.4 Kbps | 32 DH+ messages per DH+ Module | Remote I/O Scanner: 32 logical rack/channel; 16 block-transfer/channel | 32 |
1770-CD | Belden 9463 twin axial cable; connects communication module to DH+ Network | ||||
9300-RADKIT | Remote access dial-in kit: 56 Kbps modem connection to DH+ Network devices. Kit includes: Pre-configured Modem, Communication Module, DIN rail mounting hardware, and associated cables. |
FOUNDATION Fieldbus Linking Devices
FOUNDATION Fieldbus networks are designed for distributed control of process applications. The Fieldbus network is linked to other plant networks with the following bridge devices. Although these linking devices can accommodate up to 16 devices per H1 link, 8 to 10 devices per link is recommended.
Part Number | Fieldbus Application | Communication Rate | H1 Ports | Devices per H1 Link | Total Device Links Available |
1757FFLD2 | EtherNet/IP Network Bridge | Fieldbus: 31.25 Kbps EtherNet/IP: 10/100 Mbps | 2 | 16 | 32 |
1757-FFLD4 | EtherNet/IP Network Bridge | Fieldbus: 31.25 Kbps EtherNet/IP: 10/100 Mbps | 4 | 16 | 64 |
1757-FFLDC2 | ControlNet Network Bridge | Fieldbus: 31.25 Kbps ControlNet: 5 Mbps | 2 | 16 | 32 |
1757-FFLDC4 | ControlNet Network Bridge | Fieldbus: 31.25 Kbps ControlNet: 5 Mbps | 4 | 16 | 64 |
Allen Bradley ControlLogix Integrated Motion
Options include SERCOS and/or analog interface modules. Analog modules require the use of a removable terminal block (RTB).
Requirements for integrated motion include either an EtherNet/IP communication module, a SERCOS interface module, or an analog interface module along with associated cables and a removable terminal block (RTB) if analog interface is chosen. Also needed is the various drives, motors and accessories required to complete the system. These selections can be made easier by referring to the following tables.
Integrated Motion on an EtherNet/IP Network
Product | Selection Considerations |
Drive that supports EtherNet/IP connections | Unlimited Velocity, Torque, and Vhz configured drives: Kinetix 65000 Drives Kinetix 5500 Drives Kinetix 350 Drives Powerflex 755 Drives |
ControlLogix Controller | Up to 100 Drives per Controller |
ControlLogix Ethernet/IP Communication Module | 1... 8 Position Configured Drives/1756-EN2TR Module 1... 255 Position Configured Drives/1756-EN3TR Module |
SERCOS Interface Modules
Many options are available by coupling Rockwell PanelView and PanelView Plus CE electronic operator interfaces with Rockwell Automation industrialized personal computer hardware.
Part Number | Description | Number of Axis | Use With Servo Drives |
1756-M16SE | Rockwell Automation SERCOS Interface Modules | 16 | 2093 Kinetix 2000 multi-axis; 2094 Kinetix 6000 multi-axis; 2099 Kinetix 7000 multi-axis; 2098 Ultra 3000 SERCOS |
1756-M08SE | 8 | ||
1756-M03SE | 3 | ||
1756-M08SEG | SERCOS Interface Drives/Extended Pack Profile Compliant | 8 |
Analog Motion Interface Modules
Part Number | Description | Number of Axis |
1756-M02AE | Analog Servo Interface Drives with Quadrature Feedback | 2 |
1756-HYD02 | Analog, Hydraulic Servo Interface Drives LDT Feedback | 2 |
1756-M02AS | Analog Servo Interface Drives with SSI Feedback | 2 |
Allen Bradley ControlLogix I/O Modules
Choose from digital, analog, RTD, motion, thermocouple, and specialty modules. Further options include field-side diagnostics, individually isolated inputs and/or outputs, and electronic fusing. Each module requires a remote terminal block (RTB).
Your selection process will include not only the I/O requirements of the system but also the characteristics of the modules. Input/Output modules can cover many applications, from high speed digital to process control. By the use of a “producer/consumer” model, the ControlLogix system can share input information and output status with many controllers over the entire system. Some modules feature field-side diagnostics, electronic fusing, and/or individually isolated inputs or outputs. You will need to select a remote terminal block (RTB) or a 1492 interface module (IFM) to connect all field wiring for each module. The following tables list the various input/output module options available.
AC Digital Input Modules
Part Number | Inputs | Voltage Category | Operating Voltage Range | Removable Terminal Block (RTB) |
1756-IA8D | 8 Diagnostic (4 points/group) | 120 VAC | 79... 132 VAC | 1756-TBNH 1756-TBSH |
1756-IA16 | 16 (8 points/group) | 120 VAC | 74... 132 VAC | 1756-TBNH 1756-TBSH |
1756-IA16I | 16 Individually Isolated | 120 VAC | 74... 132 VAC | 1756-TBCH 1756-TBS6H |
1756-IA32 | 32 Diagnostic (4 points/group) | 120 VAC | 74... 132 VAC | 1756-TBCH 1756-TBS6H |
1756-IM16I | 16 Individually Isolated | 240 VAC | 159... 265 VAC | 1756-TBCH 1756-TBS6H |
1756-IN16 | 16 (8 points/group) | 24 VAC | 10... 30 VAC | 1756-TBNH 1756-TBSH |
AC Digital Output Modules
Part Number | Outputs | Voltage Category | Operating Voltage Range | Removable Terminal Block (RTB) |
1756-OA8 | 8 (4 points/group) | 120/240 VAC | 79... 265 VAC | 1756-TBNH 1756-TBSH |
1756-OA8D | 8 Diagnostic, Electronically Fused (4 points/group) | 120 VAC | 74... 132 VAC | 1756-TBNH 1756-TBSH |
1756-OA8E | 8 Electronically Fused (4 points/group) | 120 VAC | 74... 132 VAC | 1756-TBNH 1756-TBSH |
1756-OA16 | 16 Mechanically Fused/ Group (8 points/group) | 120/240 VAC | 74... 265 VAC | 1756-TBNH 1756-TBSH |
1756-OA16I | 16 Individually Isolated | 120/240 VAC | 74... 265 VAC | 1756-TBCH 1756-TBS6H |
1756-ON8 | 8 (4 points/group) | 24 VAC | 10... 30 VAC, >50mA 16... 30 VAC, <50ma td="td">50ma> | 1756-TBNH 1756-TBSH |
DC Digital Input and Output Modules
Allen-Bradley delineates between the various digital DC modules by sorting them into two categories: Sinking and Sourcing. As an engineer designing your own system it will help you to understand the difference between these two options. Here is the definition as given by Allen-Bradley:
"Sinking and Sourcing are terms used to describe a current signal flow relationship between field input and output devices in a control system and their power supply.
- Field devices connected to the positive side (+V) of the field power supply are sourcing field devices.
- Field devices connected to the negative side (DC Common) of the field power supply are called sinking field devices.
To maintain electrical compatibility between field devices and the programmable controller system, this definition is extended to the input/output circuits on the digital I/O modules.
- Sourcing I/O circuits supply (source) current to the sinking field devices.
- Sinking I/O circuits receive (sink) current from sourcing field devices.
Europe: DC sinking input and sourcing output module circuits are the commonly used options"
DC Digital Input Modules
Part Number | Inputs | Voltage Category | Operating Voltage Range | Removable Terminal Block (RTB) |
1756-IB16IF | 16 High Speed Individually Isolated | 12/24 VDC sink/source | 10... 30 VDC | 1756-TBCH 1756-TBS6H |
1756-IB16 | 16 (8 points/group) | 12/24 VDC sink | 10... 31.2 VDC | 1756-TBNH 1756-TBSH |
1756-IB16D | 16 Diagnostic (4 points/group) | 12/24 VDC sink | 10... 30 VDC | 1756-TBCH 1756-TBS6H |
1756-IB16I | 16 Individually Isolated | 12/24 VDC sink/source | 10... 30 VDC | 1756-TBCH 1756-TBS6H |
1756-IB16ISOE | 16 Individually Isolated, Sequence of Events | 24/48 VDC sink/source | 10... 55 VDC | 1756-TBCH 1756-TBS6H |
1756-IB32 | 32 (16 points/group) | 12/24 VDC sink | 10... 31.2 VDC | 1756-TBCH 1756-TBS6H |
1756-IC16 | 16 (8 points/group) | 48 VDC sink | 30... 55 VDC @ 60°C 30... 60 VDC @ 55°C | 1756-TBNH 1756-TBSH |
1756-IG16 | 16 (8 points/group) | 5 VDC TTL source (Low=True) | 4.5... 5.5 VDC | 1756-TBNH 1756-TBSH |
1756-IH16I | 16 Individually Isolated | 125 VDC sink/source | 90... 146 VDC | 1756-TBCH 1756-TBS6H |
1756-IH16ISOE | 16 Individually Isolated, Sequence of Events | 125 VDC sink/source | 90... 140 VDC | 1756-TBCH 1756-TBS6H |
1756-IV16 | 16 (8 points/group) | 12/24 VDC | 10... 30 VDC | 1756-TBNH 1756-TBSH |
1756-IV32 | 32 (16 points/group) | 12/24 VDC | 10... 30 VDC | 1756-TBCH 1756-TBS6H |
DC Digital Output Modules
Part Number | Outputs | Voltage Category | Operating Voltage Range | Removable Terminal Block (RTB) |
1756-OB16IEF | 16 High Speed, Individually Isolated, Electronically Fused | 24 VDC sink/source | 10... 30 VDC | 1756-TBCH 1756-TBS6H |
1756-OB8 | 8 | 12/24 VDC source | 10... 30 VDC | 1756-TBNH 1756-TBCH |
1756-OB8EI | 8 Individually Isolated, Electronically Fused | 12/24 VDC | 10... 30 VDC | 1756-TBNH 1756-TBSH |
1756-OB8I | 8 Individually Isolated | 12/24 VDC | 10... 30 VDC | 1756-TBCH 1756-TBS6H |
1756-OB16D | 16 Diagnostic (8 points/group) | 24 VDC source | 19.2... 30 VDC | 1756-TBCH 1756-TBS6H |
1756-OB16E | 16 Electronically Fused (8 points/group) | 12/24 VDC source | 10... 31.2 VDC | 1756-TBCH 1756-TBS6H |
1756-OB16I | 16 Individually Isolated | 12/24 VDC sink/source | 10... 30 VDC | 1756-TBCH 1756-TBS6H |
1756-OB16IS | 16 Individually Isolated, 8 Scheduled | 12/24 VDC sink/source | 10... 30 VDC | 1756-TBCH 1756-TBS6H |
1756-OB32 | 32 (16 points/group) | 12/24 VDC source | 10... 31.2 VDC | 1756-TBCH 1756-TBS6H |
1756-OC8 | 8 (4 points/group) | 48 VDC source | 30... 60 VDC | 1756-TBNH 1756-TBSH |
1756-OG16 | 16 (8 points/group) | 5 VDC TTL source (Low=True) | 4.5... 5.5 VDC | 1756-TBNH 1756-TBSH |
1756-OH8I | 8 Individually Isolated | 120 VDC | 90... 146 VDC | 1756-TBCH 1756-TBS6H |
1756-OV16E | 16 Electronically Fused (8 points/group) | 12/24 VDC sink | 10... 30 VDC | 1756-TBNH 1756-TBSH |
1756-OV32E | 32 Electronically Fused (16 points/group) | 12/24 VDC sink | 10... 30 VDC | 1756-TBCH 1756-TBS6H |
Contact Output Modules
Part Number | Outputs | Operating Voltage Range | Removable Terminal Block (RTB) |
1756-OW16I | 16 Normally Open Individually Isolated | 5... 150 VDC 10... 265 VAC | 1756-TBCH 1756-TBS6H |
1756-OX8I | 8 Normally Open 8 Normally Closed Individually Isolated (2 points/group) | 5... 150 VDC 10... 265 VAC | 1756-TBCH 1756-TBS6H |
Analog Input Modules
Part Number | Inputs | Range | Resolution | Removable Terminal Block (RTB) |
1756-IF6CIS | 6 Individually Isolated, Current Sourcing | 0... 21 mA | 16 Bits 0.34 µA/bit | 1756-TBNH 1756-TBSH |
1756-IF6I | 6 Individually Isolated | ±10.5 V 0... 10.5 V 0... 5.25 V 0... 21 mA | 16 Bits 10.5 V: 343 µV/bit 0... 10.5 V: 171 µV/bit 0... 5.25 V: 86 µV/bit 0... 21 mA: 0.34 µA/bit | 1756-TBNH 1756-TBSH |
1756-IF8 | 8 Single-ended, 4 Differential, 2 High Speed Differential | ±10.25 V 0... 10.25 V 0... 5.125 V 0... 20.5 mA | ±10.25 V: 320 µV/cnt(15 bits+) 0... 10.25V: 160 µV/cnt(16 bits) 0... 5.125 V: 80 µV/cnt(16 bits) 0... 20.5 mA: 0.32 µV/cnt(16 bits) | 1756-TBCH 1756-TBS6H |
1756-IF8H | 8 Differential, Current or Voltage, HART Interface | ±10V; 0... 5 V; 1... 5 V; 0... 10 V; 0... 20 mA; 4... 20 mA | 16... 21 Bits | 1756-TBCH 1756-TBS6H |
1756-IF16 | 16 Single-ended, 8 Differential or 4 Differential High Speed | ±10.5 V 0... 10.5 V 0... 5.25 V 0... 21 mA | 16 Bits 10.5 V: 343 µV/bit 0... 10.5 V: 171 µV/bit 0... 5.25 V: 86 µV/bit 0... 21 mA: 0.34 µA/ bit | 1756-TBCH 1756-TBS6H |
1756-IF16H | 16 Differential Current, HART Interface | 0... 20 mA 4... 20 mA | 16... 21 Bits | 1756-TBCH 1756-TBS6H |
1756-IR6I | 6 Individually Isolated RTD | 487 Ω 1000 Ω 2000 Ω 4020 Ω | 16 Bits 487 Ω: 7.7 mΩ/bit 1000Ω : 15 mΩ/bit 2000 Ω: 30 mΩ/bit 4020 Ω: 60 mΩ/bit | 1756-TBNH 1756-TBSH |
1756-IT6I | 6 Individually Isolated Thermocouple; 1 CJC | -12... 78 mV -12... 30 mV | 16 Bits -12... 78 mV: 1.4 µV/bit -12... 30 mV: 0.7 µV/bit | 1756-TBNH 1756-TBSH |
1756-IT6I2 | 6 Individually Isolated Thermocouple; 2 CJC | -12... 78 mV -12... 30 mV (High Resolution Range) | 16 Bits -12... 78 mV: 1.4 µV/bit -12... 30 mV: 0.7 µV/bit | 1756-TBNH 1756-TBSH |
Analog Output Modules
Part Number | Outputs | Range | Resolution | Removable Terminal Block (RTB) |
1756-OF4 | 4 Voltage or Current | ±10.4 V 0... 21 mA | Voltage: 15 bits, 320 µV/bit Current: 15 bits, 650 nA/bit | 1756-TBNH 1756-TBSH |
1756-OF6CI | 6 Individually Isolated, Current | 0... 21 mA | Current: 13 bits, 2.7 µA | 1756-TBNH 1756-TBSH |
1756-OF6VI | 6 Individually Isolated, Voltage | ±10.5 V | 21 V: 14 bits, 1.3 mV 10.5 V: 13 bits + sign bit | 1756-TBNH 1756-TBSH |
1756-OF8 | 8 Voltage or Current | ±10.4 V 0... 21 mA | 10.4 V: 15 bits, 320 µV/bit 21 mA: 15 bits, 650 nA/bit | 1756-TBNH 1756-TBSH |
1756-OF8H | 8 Voltage or Current, HART Interface | ±10.4 V 0... 20 mA 4... 20 mA | 15... 16 bits | 1756-TBNH 1756-TBSH |
Analog Combination Input/Output Module
Part Number | Inputs/Outputs | Range | Resolution | Removable Terminal Block (RTB) |
1756-IF4FX0F2F | 4 High Speed, Sub-millisecond, Differential Inputs; 2 High Speed Voltage or Current Outputs | Input: ±10.5 V 0... 10.5 V 0... 5.25 V 0... 21 mA Output: ±10.4 V 0... 21 mA | Input: Apx. 14 Bits across ±10.5 VDC = 21 V Total, 1.3 mV/bit, 14 bit effective; 0... 10.5 V, 1.3 mV/bit, 13 bit effective; 0... 5.25 V, 1.3 mV/bit, 12 bit effective; Apx. 12 Bits across 21 mA 0... 21 mA, 5.25 µA/bit Output: 13 bits across 21 mA = 2.8 µA/bit; 14 bits across 21.8 V = 1.3 mV/bit | 1756-TBCH 1756-TBS6H |
Specialty Input/Output Modules
Part Number | Inputs/Outputs | Description | Removable Terminal Block (RTB) |
1756-LSC8XIB8I | 8... 24 VDC Counters; 8 High Speed 24 VDC Inputs | Low Speed Counter Module 8... 40 kHz 24 VDC Counters; 8 High Speed 24 VDC Auxiliary Inputs | 1756-TBCH 1756-TBS6H |
1756-CFM | 4 Inputs – 2 per channel; 2 Outputs – current sourcing | Configurable Flowmeter Module 2 Flowmeter (F) Inputs for all modes; 2 Gate Inputs for Totalizer Mode for prover/store count | 1756-TBNH 1756-TBSH |
1756-HSC | 2 Counters, each with 3 Inputs (A, B, Z for Gate/Reset); 4 Outputs (2 points/group) | High Speed Counter Module 5 V Operation: 4.5... 5.5 VDC; 12/24 V Operation: 10... 31.2 VDC | 1756-TBCH 1756-TBS6H |
1756-PLS | Left Section: 2 Groups of 4 Outputs/Inputs each; Center Section: Resolver Interface and I/O Control; Right Section: 2 Groups of 4 Outputs/Inputs each | Programmable Limit Switch Module | Requires 3 RTBs: 1756-TBNH 1756-TBSH |
HART Smart Instrumentation
HART (Highway Addressable Remote Transmitter) is an industry standard protocol used to connect analog devices. The following interfaces are available for connecting HART devices.
If Your Application: | Select | Description |
Has Analog and HART Connectivity in one Module; Needs No External Hardware to Access HART Signal; Can Transmit HART Commands as Unscheduled Messages; Supports Asset Management Software to HART Device | 1756-IF8H 1756-IF16H 1756-OF8H | Rockwell Automation Analog I/O Modules |
Has Data Acquisition/Control Application With Slow Update Requirements (Such as Tank Farm); Needs No External Hardware to Access HART Signal; Does Not Connect Directly to Asset Management Software | MVI56-HART | Prosoft Interface |
Has Analog and HART in one Module; Has Instrumentation in Hazardous Areas (Flex EX Modules); Can Transmit HART Commands as Unscheduled Messages; Directly Connects Asset Management Software to HART Devices | 1794FLEX I/O 1797 FLEX Ex I/O | There are Specific FLEX I/O and FLEX Ex Modules for HART Systems. These Catalog Numbers end in H, such as 1797-IE8H |
Input/Output Module Accessories
There are two methods of providing wiring connections between the 1756 Input/Output Modules and your plant wiring system: Removable Terminal Blocks (RTBs) and prefabricated wiring cable systems that attach directly to the module. Descriptions of both options are listed below. Note that if you select the RTB option and are using 14 gauge or heavier wire you will need to select an extended depth RTB housing (1756-TBE) for each RTB used.
Removable Terminal Blocks (RTBs)
RTB Part Number | 1756-TBNH | 1756-TBSH | 1756-TBCH | 1756-TBS6H | |
Description | 20 Position NEMA Screw Clamp RTB | 20 Pin Spring Clamp RTB/Standard Housing | 36 Pin Cage Clamp RTB/Standard Housing | 36 Pin Spring Clamp RTB/Standard Housing | |
Screw Torque | 0.8... 1 N/m 7... 9 lb/in | 0.4 N/m 4.4 lb/in | |||
Screwdriver Width | 8 mm – 5/16 in. Maximum |
Wiring Cable Systems
Instead of using RTBs and connecting the module wiring on-site you can elect the following wiring system options:
- Interface Modules (IFMs) provide output terminal blocks for digital input/output modules. You select pre-wired cables matching the digital I/O module to the IFM.
- Analog Interface Modules (AIFMs) provide output terminal blocks for analog I/O modules. You select pre-wired cables matching the analog I/O module to the AIFM.
- I/O Module Ready Cables are a prefabricated wiring assembly in which one end is an RTB that plugs directly into the input/output module. The other end of the assembly has color-coded conductors that connect directly to an industry standard terminal block.
Allen Bradley ControlLogix Power Supplies
Available to provide 1.2V, 3.3 V, 5 V, and 24 V DC power. Requires one power supply per chassis for standard systems, or a power supply bundle can be selected for redundant systems.
Your options include one power supply for each chassis in a standard system or a power supply bundle in a redundant system. Power supplies mount on the left end of the chassis and plug directly into the backplane. Redundant power supplies provide additional uptime protection for ControlLogix systems used in critical applications. Consult the following table for the appropriate power supply for your system.
Part Number | Description | Voltage Category | Operating Voltage Range | Chassis |
1756-PA72 | Standard AC Power Supply | 120VAC/220VAC | 85... 265VAC | Standard, Series A & B |
1756-PA75 | 120VAC/220VAC | 85... 265VAC | Standard, Series B | |
1756-PB72 | Standard DC Power Supply | 24 VDC | 18... 32 VDC | Standard, Series A & B |
1756-PB75 | 24 VDC | 18... 32 VDC | Standard, Series B | |
1756-PC75 | 48 VDC | 30... 60 VDC | Standard, Series B | |
1756-PH75 | 125 VDC | 90... 143 VDC | Standard, Series B | |
1756-PAXT | ControlLogix-XT AC power Supply | 85... 265VAC | 120VAC/240VAC | XT |
1756-PBXT | ControlLogix-XT DC power Supply | 24 VDC | 18... 32 VDC | XT |
1756-PA75R/A | Redundant AC Power Supply/2 Needed | 120VAC/220VAC | 85... 265VAC | Standard, Series B |
1756-PB75R/A | Redundant DC Power Supply/2 Needed | 24 VDC | 19.2... 32 VDC | |
1756-PAR2 | Bundled Kit With: Two 1756 PA75R Power Supplies, Two 1756-CPR2 Cables, & One 1756-PSCA2 Chassis Adapter Module | 110 VAC | N/A | |
1756-PBR2 | Bundled Kit With: Two 1756 PB75R Power Supplies, Two 1756-CPR2 Cables, & One 1756-PSCA2 Chassis Adapter Module | 24 VDC | N/A | |
1756-CPR2 | Redundant Power Supply Cable/2 Needed - Length: 3 Ft | N/A | N/A | |
1756-PSCA2 | Redundant Power Supply Chassis Adapter Module | N/A | N/A | |
Annunciator Wiring | User Supplied Wiring connects to solid-state relays for status/troubleshooting: 2 Needed Maximum Length: 10 Ft. | N/A | N/A |
Allen Bradley ControlLogix Chassis
Both standard and extreme temperature models are available. Standard chassis are available with 4, 7, 10, 13, or 17 slots, while the extreme temperature (XT) chassis comes in 5 or 7 slot models. All empty slots require slot fillers.
Choose chassis with the necessary slots available for all your system requirements, as well as slot fillers. Any module can be placed in any slot of the chassis. All of the chassis support horizontal, back panel mounting. Chassis specifications are outlined in the following table. All empty slots must use a slot filler.
Part Number | Description | Slots | Operating Temperature |
1756-A4 | Standard ControlLogix Chassis | 4 | Standard Operating Temperatures |
1756-A7 | 7 | ||
1756-A10 | 10 | ||
1756-A13 | 13 | ||
1756-A17 | 17 | ||
1756-A4LXT | ControlLogix-XT Extreme Temperature, Extreme Environment Chassis | 4 | -25... 60ºC (-13... 140ºF) |
1756-A5XT | 5 | -25... 70ºC (-13... 158ºF) | |
1756-A7XT | 7 | ||
1756-A7LXT | 7 | -25... 60ºC (-13... 140ºF) | |
1756-N2 | Standard ControlLogix Chassis Slot Filler | ||
1756-N2XT | Extreme Temperature ControlLogix-XT Slot Filler |
Allen Bradley ControlLogix Software
Rockwell Software supervisory control, including FactoryTalk View software, is available. Your overall software needs will be determined by the total system configuration, including Input/Output and Communication modules selected. The ControlLogix system is programmed using RSLogix 5000 Enterprise Series software. Optional design and configuration products include RSNetworx and RSLinx software.
Software is available to make your entire system easy to program and maintain. Your selection of modules and your network configuration will determine the software packages necessary to configure and program your ControlLogix system. You will be able to choose from a wide variety of RSLogix 5000 Enterprise Series Software Packages to meet your most stringent system requirements.
This completes an overview of the process you will go through to create a ControlLogix system that will satisfy all of your current manufacturing needs plus allow the flexibility to expand the system as future needs arise. ControlLogix systems are in use worldwide in every imaginable type of manufacturing environment. As the industry standard, ControlLogix systems deliver predictable performance at competitive prices. Don't hesitate to design an up-to-date control system for your plant. Make the ControlLogix choice!
ControlLogix Visualization Products
Select the appropriate computer monitors and interfaces for your system. Rockwell Automation combines Allen-Bradley electronic operator interfaces and industrial personal computer hardware with Rockwell Software supervisory control software to provide optimum visualization products. Current products include the following:
- FactoryTalk View Software
- PanelView Plus Operator Interface
- PanelView Plus CE Operator Interface
- Industrial Computers and Monitors
PLC Training in chennai
ReplyDeletePLC Training Institute in chennai
PLC Training Center in chennai
PLC Training Course in chennai
PLC Course in chennai
PLC SCADA Training in chennai
PLC Training Centre in chennai
PLC SCADA Training Institute in chennai
Best PLC Training in chennai
Best PLC Training Institute in chennai
DCS Training in chennai
Automation Training in chennai
Automation Training Institute in chennai